94 research outputs found

    Multiple Meningioma Resection by Bilateral Extended Rostrotentorial Craniotomy with a 3D-Print Guide in a Cat.

    Get PDF
    A 13-year-old castrated male domestic shorthair cat was referred for the surgical removal of multiple meningiomas. The cat experienced generalized tonic-clonic seizures, altered mentation, mild proprioceptive ataxia, and circling. Magnetic resonance imaging (MRI) revealed two round, solitary, well-delineated, space-occupying lesions suggestive of multiple meningiomas in the right frontal and occipital lobes. Before surgery, patient-specific three-dimensional (3D) printed models and guides were produced using a 3D program based on MRI and computed tomography (CT), and a rehearsal surgery was performed. With a 3D guide to find the location of the craniotomy lines, bilateral extended rostrotentorial craniotomy allowed en bloc resection of multiple meningiomas. The bone fragment was replaced and secured to the skull with a craniofacial plate and screws with an artificial dura. All of the surgical steps were performed without complications. The preoperative presenting signs were resolved by the time of follow-up examinations 2 weeks after surgery. Twelve months after the removal of the multiple meningiomas, the cat survived without further neurological progression. For the resection of multiple meningiomas, surgery can result in large bone defects and risk of massive hemorrhage. For this challenging surgery, patient-specific 3D models and guides can be effective for accurate and safe craniotomies

    DECENTRALIZED SOCIAL NETWORK SERVICE USING THE WEB HOSTING SERVER FOR PRIVACY PRESERVATION

    Get PDF
    In recent years, the number of subscribers of the social network services such as Facebook and Twitter has increased rapidly. In accordance with the increasing popularity of social network services, concerns about user privacy are also growing. Existing social network services have a centralized structure that a service provider collects all the user’s profile and logs until the end of the connection. The information collected typically useful for commercial purposes, but may lead to a serious user privacy violation. The user’s profile can be compromised for malicious purposes, and even may be a tool of surveillance extremely. In this paper, we remove a centralized structure to prevent the service provider from collecting all users’ information indiscriminately, and present a decentralized structure using the web hosting server. The service provider provides only the service applications to web hosting companies, and the user should select a web hosting company that he trusts. Thus, the user’s information is distributed, and the user’s privacy is guaranteed from the service provider

    Biomechanical Comparison of Double 2.3-mm Headless Cannulated Self-Compression Screws and Single 3.5-mm Cortical Screw in Lag Fashion in a Canine Sacroiliac Luxation Model: A Small Dog Cadaveric Study.

    Get PDF
    OBJECTIVE  The aim of this study was to evaluate the feasibility of safe positioning of double 2.3-mm headless cannulated self-compression screws (HCS) in a small dog cadaveric sacroiliac luxation model and to compare the static rotational biomechanical properties of fixation repaired using two different screw systems with a minimally invasive osteosynthesis technique: double 2.3-mm HCS and a single 3.5-mm standard cortical screw placed in a lag fashion. STUDY DESIGN  A unilateral small dog sacroiliac luxation model was stabilized using double 2.3-mm HCS (n = 11) or a single 3.5-mm cortical screw (n = 11). Radiographic and computed tomography (CT) imaging analyses and biomechanical testing of rotational force on the sacroiliac joint of both fixations were performed. The maximum load at failure and failure modes of each fixation were recorded and compared. RESULTS  Fluoroscopically guided percutaneous application of double HCS was safe in a unilateral sacroiliac luxation model in small dogs without violation of the vertebral and ventral sacral foramen. Furthermore, resistance to rotational force applied on fixation of the sacroiliac joint repaired with double 2.3-mm HCS estimated by maximum failure load was significantly higher than that of a single 3.5-mm cortical screw (p < 0.001). CONCLUSION  Although this was an experimental cadaveric study, based on our results, the use of smaller double HCS may be beneficial as an alternative to the conventional single lag screw for stabilization of sacroiliac luxation in small dogs
    • …
    corecore